DOC PREVIEW
UW-Madison BME 200 - Intramedullary Rods

This preview shows page 1-2-3-4-5 out of 15 pages.

Save
View full document
View full document
Premium Document
Do you want full access? Go Premium and unlock all 15 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 15 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 15 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 15 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 15 pages.
Access to all documents
Download any document
Ad free experience
Premium Document
Do you want full access? Go Premium and unlock all 15 pages.
Access to all documents
Download any document
Ad free experience

Unformatted text preview:

AbstractClient InformationBackground & MotivationCurrent ProductsProblem StatementClient Design RequirementsFinal Design ConceptFinal Design ContinuedFinal Design FractureTesting MethodsForce ResultsMoment ResultsConclusionFuture WorkAcknowledgementsAbstractIntramedullary nails (IN) present one method of repairing long bone fractures. Upon insertion into the intramedullary space the nail is fastened with 2 proximal and 2 distal screws. Holes must be drilled into the bone that align with these 4 holes. Currently a jig assembly is used to guide surgeons drilling these holes. Sometimes this assembly fails to align the drill correctly resulting in insecure nails. The assembly appears to fail at the extension-nail interface. A re-designed nail-extension unit has been developed to address this issue. Initial results suggest that a solid unit with stress-raisers reduces the movement that occurred about the old connection.Client Information-R. Tass Dueland, DVM -Ray Vanderby, Professor- William L. Murphy, Professor and AdvisorBackground & Motivation•IN are ~97% effective in repairing clean long bone fractures•IN allows necessary movement to stimulate osteoblasts while providing rigid support•IN nails are not effective when not secured properly•Screws fail to fasten ~4% of the timeCurrent Products•Intramedullary Nail–Produced by Innovative Animal Products•Magnetic Targeting Device–Locates field produced by magnets in the nailFig. 2: Magnetic targeting deviceFig. 1: IN and jig assemblyProblem Statement-Decrease drill guide misalignments with the intramedullary nail holes to reduce failure rates.Client Design Requirements•Maintain integrity of the nail•Implement into current procedures•Compose of biocompatible materials•Improve fastening success rateFinal Design Concept•Eliminate extension-nail interface•Stress-raisers allow control of yield point via stress factor, Kt•Solid unit should be stronger then any threaded connectionINPush RodFig. 3: Push Rod that applies tension to nail at stress raiser.•Prototype stress raiser: t=0.5mm h=0.9mm r~0.5mm•Results in a Kt~1.6•Breaking Point: σy=485MPa (Schmid, 1999) P = ~ 3.5 KNor ~800 lbs Final Design ContinuedStress concentration factors, Kt for a tube in tension with a fillet, (ESDU 1981).KtσyAFig. 4: Variables that determine KthtrP PdiFinal Design Fracture• Fracture was not obtained with current design•Obtained with minimal outside force application•Increasing h will yield higher Kt, reduce A, and allow for a larger push rod Fig. 5: The push rod can be seen protruding from the break point.Testing Methods•Goal: Quantify force necessary to cause screw misalignment•Procedure: –A force gauge was used to apply a force at the distal end of the IN. The value was recorded upon achieving misalignment.Fig. 6: Picture depicting testing methods. The jig is clamped to the table. A force gauge is used deviate the nail.Force Results•Prototype required ~1.5X more force to deviate nail to misalignmentFig. 7: Average force applied at a constant position to deviate the nail to misaligment.Moment Results•Larger moment required to achieve deviation in prototype•Assuming this moment remains constant, a relationship between the force and where it is applied can be found.Fig. 8: Average force applied at a constant position to deviate the nail to misaligment.Conclusion•Vast improvement in resistance to bending–Greater force required to deviate nail•Stress raiser cleanly fractures•Prototype requires further modificationsFuture Work•Increase diameter of center hole–Increases diameter of plunger–Decreases fracture force•New material for plunger rod–Increase elastic and shear modulus•More testingAcknowledgements •R. Tass Dueland, DVM •Ray Vanderby, Professor •William L. Murphy, Professor•Carrie Lowrey, Surgical Assistant•UW-Madison Veterinary School•Paul Manley, DVM•Daniel Ruys, Professional Welder•Machine Shop Personnel •Jay Warrick, BME Graduate


View Full Document

UW-Madison BME 200 - Intramedullary Rods

Documents in this Course
Load more
Download Intramedullary Rods
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Intramedullary Rods and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Intramedullary Rods 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?