Fine Needle Aspiration (FNA) Device Chris Goplen, Tu Hoang Anh Mai, Kristen Seashore, Jason Tham December 12, 2006 Function: Fine needle aspiration is a biopsy method of collecting tissue samples. The procedure is currently manual and requires repetitive low yield sampling to collect enough viable cells for testing. The goal of our project is to maximize tissue sample size in a single, timely procedure. We propose to develop a device that automates the current biopsy procedure, and tests the sample yield by varying the frequency and needle stroke. The test results will determine the optimal operating frequency at various stroke lengths to provide a maximum cell yield. The automation of the device will reduce operating time, cost and discomfort for the patient. Client requirements: The device must: • be reusable • be durable • be user-friendly • be sanitary to clients standards • comply with given hospital safety standards • be dependable and precise • test variations in frequency and needle stroke Design requirements: 1) Physical and Operational Characteristics a) Performance Requirements: i) Reusable ii) Withstand constant oscillation iii) Withstand multiple procedures iv) Withstand sterilization methods v) Needle force requirements vi) Vacuum mechanism to draw cells into needle easily operated by second person b) Safety: i) No risk of electric shock ii) Non-toxic and non-allergenic iii) Preserve needle integrity c) Accuracy and Reliability: i) Variable needle insertion depth (10mm to 20mm) ii) Frequency must be variable and measurable iii) Biopsy sample must be retained within needle shaft d) Life in Service: Device must be operable over 30 minute interval e) Operating Environment:i) Sterile hospital environment ii) 23˚C standard room temperature f) Ergonomics: i) Functional at varying angles of operation without losing maneuverability ii) Controls must be easily accessible g) Size: i) Small and slender ii) Must not restrict maneuverability and accessibility h) Weight: i) Must not strain arm and hand ii) Light weight i) Materials: i) Light weight materials ii) Easily sanitized, especially materials potentially in contact with patient j) Aesthetics, Appearance, and Finish: i) Marketable (aesthetically pleasing to patient and doctor) ii) Maintains professional medical device appearance 2) Production Characteristics a) Quantity: 1 prototype b) Target Product Cost: minimal, constrained by budget 3) Miscellaneous a) Standards and Specifications: FDA approval (human testing standards) b) Customer: i) Minimal training ii) Low production costs iii) User-friendly c) Patient-related concerns: i) Sterilized between uses ii) Minimal time, cost and pain iii) Professional aesthetics d) Competition i) Manual fine needle aspiration technique ii) Cameco Syringe Gun iii) Vacuum needle iv) Fine Needle Gun (Patent


View Full Document

UW-Madison BME 200 - Fine Needle Aspiration (FNA) Device

Documents in this Course
Load more
Download Fine Needle Aspiration (FNA) Device
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Fine Needle Aspiration (FNA) Device and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Fine Needle Aspiration (FNA) Device 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?