DOC PREVIEW
UMD ENMA 490 - Device Design Stage 1: Initial Microchannel Test Design

This preview shows page 1-2 out of 7 pages.

Save
View full document
View full document
Premium Document
Do you want full access? Go Premium and unlock all 7 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 7 pages.
Access to all documents
Download any document
Ad free experience
Premium Document
Do you want full access? Go Premium and unlock all 7 pages.
Access to all documents
Download any document
Ad free experience

Unformatted text preview:

Device Design Stage 1: Initial Microchannel Test DesignDevice Logic:Materials:Processing Method with Mask DesignDevice Design Stage 1: Initial Microchannel Test DesignDevice Objective:Once the design requirements and assumptions were finalized, the group determined that testing preliminary designs on the path to a final design was necessary to ensure constant feedback to assess the practicality of design choices. In this path, the testing of the fluidic channels was of primary importance, as the option of including control elements would be mute if the fluid itself was unable to pass through the channels designed. Therefore, the group generated the Initial Microchannel Test Design. The purpose of this device was to allow the group to test the experimental capabilities available to us, as well as establish a base upon which more complicated devices could be modeled. More specifically, the device was designed to test the viability of basic multi-level micro-fluidic devices with the equipment and materials currently available. Device Logic: The design that was chosen consisted of the simplest two-channel layer three-dimensional channel geometry that could be constructed, and at the same time test the practicality of multi-level microfluidics. Moreover, the group decided to use sequential layers of PDMS molds to build up the desired structure. These molds were to be stacked on a bare silicon wafer, which would provide rigidity for transport and testing. There were several reasons for this choice, which included the following:1. The PDMS layers would allow for heightened design flexibility, as the molds could be re-used and the layers created from these molds could be stacked numerous times in several different orientations.2. The existing knowledge available to the group based on prior experimental tests done on similar processes by students in the department.3. The known material compatibility between PDMS and many biological agents that could be used in multi-level micro fluidic devices.4. The equipment and material constraints based on availability, or lack thereof, of potential materials and equipment for other, less common forms of microprocessing.5. The PDMS and SU8 molding process was known to have a relatively fast turnaround time, and this was critical due to the time constraints on the semester.Figure 1 below shows a schematic of the proposed design. The colors (blue, green, and yellow) signify voids within the PDMS (white). The design consists of three layers: one interconnect layer, and two microchannel layers. The lower microchannel layer (shown in blue) connects to the interconnect pegs (shown in green), which in turn, connect to the top microchannel layer (shown in yellow). The circles located at the ends of the microchannels are the reservoirs which run from the top to the bottom layer, and provide top down access points to all the microchannels, thus allowing for fluid access to all microchannels to assist in testing. Fluid flow into anyone of the 12 reservoir inputs would allow the fluid to enter the device and test to ensure the fluid was able to stay within the pre-determined microchannels that were constructed, as opposed to forcing between the layers and resulting in layer delamination. Micro-Channel Layer 1Micro-Channel Layer2Interconnect LayerFigure 1: A Schematic of the Initial Microchannel Test Design (Top View)Device Dimensions: Based on the logic of the design, the group then determined some appropriate dimensions. Given that this was the first design stage of the semester, there were only a few constraints on the dimensions that could be chosen, so the dimensions were chosen based on the approximate sizes encountered in most of the literature. The only constraints that were considered during the device dimensioning were the overall silicon wafer size of diameter = 4 inches and the fact that the PDMS layers could not be molded to a thickness greater thenapproximately 100m, given past experimental use with the material. Below in Table 1 is a summary of all the critical dimensions that were determined for this Initial Microchannel Test Design. These dimensions were chosen very loosely as the purpose of this design was to test the general performance of the design proposal and not the specifics of the device geometry.Table 1: A Table of the critical dimensions for the Initial Microchannel Test DesignCritical Dimension ValuePDMS Layer Height100mMicrochannel Width150mMicrochannel Length 45mmInterconnect Width150mInterconnect Depth150mReservoir Diameter300mDistance Between Channels300mThe cross sections of the microchannels were process limited, as the SU8 and PDMS molding process does not easily allow for the creation of ridges or grooves that are non-rectangular. Therefore, the cross-section the microchannels were made rectangular. Given the different orientation of the reservoirs and interconnects relative to the micro channels, they couldhave been made any number of shapes, however, for simplicity, the interconnects were made square in cross-section and the reservoirs were made circular in cross-section. These dimensions and geometry constituted, what the group thought as, the most basic design option to test the viability of multi-level micro-fluidic devices .Materials: In the introductory sections, we gave a list of materials that are candidates for this projectand an overview of their electrical and mechanical properties. In this section, we will be discussing the materials that are used, as well as why they are used. At this stage, the materials used for fabrication of our device are silicon, SU-8 and PDMS(polydimethyl siloxane). We selected a silicon wafer as our substrate because it is cheap and convenient for most of the fabrication processes like lithography. PDMS is a soft polymer that has attractive physical properties, in addition to a low cost. Fabricating PDMS involves a lithographic process. It’s physical properties include elasticity, conformality, optical transparency, etc. Devices made of PDMS can be integrated with other components, since PDMSconforms to materials like silicon or glass easily. This conformal property makes both reversibleand irreversible sealing possible. It is non-toxic to biological agents, such as proteins, and it is gas permeable. Also, since it is transparent in the visible/UV region, it is compatible with many optical detection methods. SU-8 is a negative based epoxy photo-resist


View Full Document

UMD ENMA 490 - Device Design Stage 1: Initial Microchannel Test Design

Documents in this Course
Load more
Download Device Design Stage 1: Initial Microchannel Test Design
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Device Design Stage 1: Initial Microchannel Test Design and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Device Design Stage 1: Initial Microchannel Test Design 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?