DOC PREVIEW
UW-Madison PHYSICS 208 - Lab 11- Radioactivity

This preview shows page 1-2 out of 5 pages.

Save
View full document
View full document
Premium Document
Do you want full access? Go Premium and unlock all 5 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 5 pages.
Access to all documents
Download any document
Ad free experience
Premium Document
Do you want full access? Go Premium and unlock all 5 pages.
Access to all documents
Download any document
Ad free experience

Unformatted text preview:

Lab 11: Radioactivity Phy208 Spring 2008 Name_____________________________ Section___________ This sheet is the lab document your TA will use to score your lab. It is to be turned in at the end of lab. To receive full credit you must use complete sentences and explain your reasoning clearly. What’s this lab about? This is the second lab about quantum mechanics. Your goal is to learn about particles emitted in radioactive decay, and about the decay process. You do this by measuring the penetrating power of these particles through various materials: Lead, Aluminum, and Plastic. You investigate two different radioactive sources 60Co (cobalt-60) and 204Tl (thallium-204) - here are their properties: Particle emitted Particle energy Half-life 60Co photon 1.3 MeV 5.3 years 204Tl electron Max 0.75 MeV 3.8 years Why are we doing this? Radioactive materials are all around us. Many occur naturally in small abundances, and many are artificially enriched for technological applications, primarily for applications in medicine. What should I be thinking about before I start this lab? You should think about radioactive decay as being a random process, where there is a certain probability for the nucleus to emit a particle. Also think about what this particle is, where it came from, and how it might interact with the matter that it passes through.2 You will measure the penetrating power of this radiation through different thicknesses of aluminum and lead for 60Co, and through plastic for 204Tl. Since the measurement procedures are all the same, your lab group investigates only one combination of source and absorber, then you record other group’s data at the end, so that you will have data for all different source/absorber combinations. You will find multiple absorbers of the same type and thickness on your lab table. We will be doing only section MPC-1b of the MPC-1 lab. Should take 1 hour. Your TA will distribute radioactive source(s) to your group. If you work with a 204Tl beta emitter (plastic (poly) absorber), your TA will remove the plastic cap from your Geiger counter (the electrons can’t penetrate through much at all). Groups using the 60Co source (Al or Pb absorber) should leave the caps on to protect the (very thin and fragile) detector window. Group 1: Two 60Co source on top of each other in slot #5 (from top). Use 0, 1, 2, and 3 lead absorbers (each 0.25” thick). [two lab tables] Group 2: Four 60Co sources on top of each other in very bottom slot. Use 0, 2, 4, and 6 “triple” aluminum absorbers (each “triple” absorber has three 1/8” sheets, so 3/8” thick) [one table] Group 3: Two 204Tl sources on top of each other in slot #5 with writing side down. Use 0, 1, 2 and 3 ‘D’ poly absorbers (each 0.010” thick). (Remove plastic Geiger counter protective cap) [rest of lab tables] 1) Go to the course web page and click on the Lab11Settings file on the “Laboratories” page to start up the PASCO software. 2) First you need to measure the background radiation level. Turn on your Geiger counter by plugging it into input 1 of the PASCO interface. Make sure any radioactive sources are at least 1 m away. The Geiger counter should click periodically, as it detects cosmic rays and other background radiation. Take data with the PASCO interface for 300 seconds (it will stop automatically). What is the background count rate (average counts / second)? Remember there are 10 sec in each “data sample” 3) Put the appropriate number of sources on the clear tray, and slide the tray in the appropriate slot (see above). Make sure the side without writing faces the detector, and for 204Tl make sure that the plastic cap is removed from the Geiger counter. Click start and let it run for until it stops (300 sec). Determine the mean number of counts / second from the radioactive source by subtracting the background signal There are 10 sec in each “data sample”. While the data is accumulating, complete part 4 on the next page.3 4) Radioactive decay is a random process, so that the decay of any individual nucleus cannot be predicted. As your data shows, the number of decays in each ten-second interval varies quite a bit. In each short time interval ! dt an individual nucleus has the same fixed probability rdt of decaying. r is the decay rate of an individual nucleus. Think of this as rolling a die once per second trying to get a six, which here means ‘decayed’. Each roll tells you whether the nucleus decayed in that dt of 1 second. Each time you roll, you have the same 16.7% chance to get a six, so the decay rate r is 0.167/s. For radioactive nuclei, the decay rate is much smaller, which you can think of as rolling a cup of many dice once per second, trying to get all sixes (how often have you gotten all sixes in Yahtzee?). The measured decays per second in your experiment is proportional to the number of radioactive nuclei in the sample. The average number ! Ndecay that decay in a time interval ! dt is ! Ndecay= Nrdt where N is the total number of radioactive nuclei. Once they decay, the number of radioactive nuclei has decreased. The number remaining after time t works out to be ! N = Noe"r t where No is the number at t=0. But usually the half-life t1/2, not the decay rate, is specified for a radioactive material. The relation between them is ! t1/ 2= ln(2) / r " 0.69 / r. a. Use the listed half-life to calculate the decay rate (in sec-1) of a single nucleus in your radioactive source. b. When you roll N dice, there are 6N possible ways for them to come up, but only one of these is all sixes. About how many dice would you have to roll once per second to make the rate of getting all sixes the same as your radioactive source decay rate? c. The number of decays per second you measured in part 3) are only a fraction of the total number of decays. First, the radiation goes in all directions, but the detector intercepts only a fraction ! "rwindow2/ 4"rsample2, (rwindow=4.6mm is the detector window radius, rsample is the distance of the source(s) from the detector window. Second, the detector is only 10% efficient (counts only 10% of the entering particles). Use your result from part 3 to find the number of radioactive nuclei in your source.4 5) In


View Full Document

UW-Madison PHYSICS 208 - Lab 11- Radioactivity

Documents in this Course
Lect 11

Lect 11

19 pages

EM Waves

EM Waves

23 pages

Exam 3

Exam 3

5 pages

Load more
Download Lab 11- Radioactivity
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Lab 11- Radioactivity and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Lab 11- Radioactivity 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?