DOC PREVIEW
UB MAE 334 - Introduction to Instrumentation and Computers

This preview shows page 1-2-3 out of 8 pages.

Save
View full document
View full document
Premium Document
Do you want full access? Go Premium and unlock all 8 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 8 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 8 pages.
Access to all documents
Download any document
Ad free experience
Premium Document
Do you want full access? Go Premium and unlock all 8 pages.
Access to all documents
Download any document
Ad free experience

Unformatted text preview:

Department of Mechanical and Aerospace Engineering MAE334 - Introduction to Instrumentation and Computers Midterm Examination October 19, 2005 o Closed Book and Notes o Fill in your name on your scoring sheet o Fill in your 8-digit person number on your scoring sheet. o For each question, choose THE BEST ANSWER and mark the corresponding answer on the scoring sheet. o The student-t table is on the last page of the examFill in circle 1 under GRADE OR EDUCATION on your scoring sheet. This is your test number! You will receive a ZERO if you do not indicate your test number. First Order Sensor Response0123456789101112012345678910Time (sec)y(t) (volts)Temp T(t)Step Function Figure 1. Time response output of a first order system subjected to a step input function. 1. What is the approximate time constant of the first order system plotted in Figure 1? a. 2 b. 3 c. 4.5 d. >10 e. None of the above 2. If the time constant of the thermocouple used in Lab 2 had changed from 2 seconds for the water-to-water experiments to 200 seconds for the water-to-air experiments what would explain the difference? a. The convective heat transfer coefficient increased by a factor of 100. b. The convective heat transfer coefficient decreased by a factor of 100. c. The thermal capacity of the thermocouple is 100 times greater in air. d. The specific heat of air is 100 times larger than water. e. None of the above. MAE 334 – Midterm Exam, October 19, 2005 2 of 8First Order Sensor Reponse Error Function-2-1.5-1-0.500.510 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5Time (sec)ln(G(t)) Figure 2. Linearized error function of a first order system subjected to a step input function. 3. The data from Figure 1 was used to obtain Figure 2? a. True b. False 4. If the static sensitivity of the thermocouple was less, the time constant would be smaller. a. True b. False 5. If the thermocouple used to obtain Figure 2 was subjected to a 5 Hz temperature fluctuation you would expect a. A minimal amplitude reduction and phase lag of the output signal b. A moderate amplitude reduction and phase lag of the output signal c. A major amplitude reduction and phase lag of the output signal d. The moon to be made of cheese 6. The MicroSoft Excel function used to obtain the student-t table value, t99%,108 would be a. =TINV(99%,108) b. =TINV(1%,108) c. =1/TINV(99%,108) d. None of the above MAE 334 – Midterm Exam, October 19, 2005 3 of 8Second Order System Reponse to a Unit Step Input Function00.20.40.60.811.21.41.61.800.511.52First ζ Second ζ Thrid ζ Figure 3. Response of a second order system to a step input function. 7. Which system response in Figure 3 has the shortest settling time? a. First b. Second c. Third d. The second and third are approximately equal e. The first and third are approximately equal 8. What is the approximate natural frequency of the first system in Figure 3? a. 0.5 Hz b. 5 Hz c. 2 Hz d. 1 Hz e. It can not be determined from the graph 9. To correctly enter the LINEST array function in MicroSoft Excel you could a. Type in the function in a cell and press Cntl+Shift+Enter b. Type in the function in a cell, then drag the cell to a 2 column by 5 row array c. Select a 2 column by 5 row array, type in the function and then press Cntl+Shift+Enter d. None of the above 10. If you have an uncalibrated instrument its bias error can be reduced by randomizing your data collection, taking a large quantity of data and repeating the experiment numerous times. a. True b. False MAE 334 – Midterm Exam, October 19, 2005 4 of 8Thermocouple Static Calibration Data051015202530354045-1000 -500 0 500 1000 1500Thermocouple Output (micro Volts)Thermometer Reading (C) Figure 4. Thermocouple static calibration plot of data from Table 1 with a linear trend line fit to the data. 11. The linear trend line in Figure 4 has how many degrees of freedom? a. 11 b. 10 c. 9 d. 8 12. For the μV vs. Temperature (°C ) data in table 1, Sx=5x(10-4), Syx=0.5, R2=0.98. What is the confidence interval for a second order fit with 90% certainty? a. ±(1.833 x 0.5) b. ±(1.812 x 0.98) c. ±(1.833 x 5x(10-4)) d. ±(1.860 x 5x(10-4)) e. None of the above 13. If the static sensitivity of a thermocouple was found to be 8192 °C/V and a bi-polar 12 bit ADC with a full scale range of 25 volts and an input signal gain of 50 was used to record the thermocouple output, what would the quantization level in °C be? Point NumberThermometer Reading [C] DMM Value (uV) 1 0.50 -616.0 2 21.00 213.0 3 41.50 1050.0 4 30.50 580.0 5 33.00 695.0 6 21.50 217.0 7 3.20 -590.0 8 40.30 984.0 9 22.00 229.0 10 14.00 -79.0 11 4.5 -533.0 Table 1. Lab 2 thermocouple static calibration dataplotted in Figure 4.a. 1 °C b. 2 °C c. none of the above MAE 334 – Midterm Exam, October 19, 2005 5 of 814. If you have a calibrated instrument its precision error can be minimized by randomizing your data collection, taking a large quantity of data and repeating the experiment numerous times. a. True b. False 15. A 4 bit ADC with a 16 volt input signal range has a finer resolution than a 8 bit ADC with a 200 volt input signal range. a. True b. False 16. The ADC used in the lab would output what binary value corresponding to -3? a. 111111111101 b. 100000000011 c. 000000000011 d. 111111111100 e. None of the above 17. Unlike a thermocouple a resistance temperature device, RTD, behaves very close to a zero order system? a. True b. False 18. Interference is considered to be a deterministic extraneous variable in an experiment? a. True b. False 19. If your static calibration data is best fit with the equation y = 4x2 + 4x + 4, then the static sensitivity is 4. a. True b. False 20. How does x relate to x′for a normally distributed data set? a. ,%Pxxxt Sν′=± b. ,%Pxxxt Sν′=± c. ,%1/2xPSxxtNν′=± d. None of the above 21. A manometer will behave as a first order system? a. True b. False 22. The regression analysis goodness of the fit is inversely proportional to the number of degrees of freedom? a. True b. False MAE 334 – Midterm Exam, October 19, 2005 6 of 823. If you sample the function sin(198πt) at 100 samples per second the data record will have frequency content at a. 198 Hz b. 99 Hz c. 49 Hz d. 2 Hz e. 1 Hz 24. The error function of a thermocouple subjected to a step input in the second lab function will vary from a. 1 to 0 b. 0 to -∞ c. T0 to T∞ d. -1 to 0 e. None of the above Figure 5. Gamma Noise signal (left) and the


View Full Document

UB MAE 334 - Introduction to Instrumentation and Computers

Download Introduction to Instrumentation and Computers
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Introduction to Instrumentation and Computers and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Introduction to Instrumentation and Computers 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?