Unformatted text preview:

AREN 3050 Environmental Systems for Buildings I FALL 2005 Project #4: Commercial Building System Design Due Friday, 9 December 2005, 5:00 p.m. This project is optional. If you elect to skip this project, the three previous projects will each be worth 8.33% of your final grade. If you elect to complete this project, it may be used to reduce the impact of a previous project or exam in the following ways: • It may replace one of the previous projects. If your score on this project is greater than the lowest score of the first three projects, it can replace the lowest score project. That is, your project with the lowest score will be discarded. • If you have performed more poorly on the exams than on previous projects, this project could reduce the impact of your worst exam score. Currently, each hour exam is worth 15% of the final grade. If your score on this project is better than your worst exam, the weighting of the exam will be reduced to 6.67% and the project will be worth the remaining 8.33%. The selection between these two options will be automatic to give you the best final grade. You are expected to perform the analysis in teams of up to two people. Perform the analysis for one of the following cities: San Diego, Fort Worth, Chicago, Memphis, and Washington, D.C. Pick the city whose first letter (C, F, N, S, W) is closest to the first letter of the surname (last name) of the youngest person in the group. Note: Use Sterling, VA, for Washington weather data. Project Description Consider a one-story small office building. You are being retained to develop a design for the building and its heating and cooling systems. The building is a one-story office and retail building with a slab on grade foundation. The building measures 200 ft in the east-west direction and 50 ft. in the north south direction. The building has a 13 ft ceiling height. The office portion of the building is the east half of the space and the retail portion is the west half, each with a floor area of 5000 ft2. There are 32 windows on both the north wall and the south wall, evenly distributed. There are no windows on the east or west. The windows are 4 ft. wide and 6 ft. tall. There is one glass door on both the east and west walls. You should consider the building to have a basic steel construction. The walls are steel studs with stucco exterior. The roof has standard steel joists with roof insulation board above the deck and a weather barrier. The electric energy rate is $0.50 per kWh and the natural gas fuel cost is $0.70 per therm (1 therm = 100,000 Btu). The electric demand charge is $10 per kW. Part 1: Basic Building System Design Envelope You are to perform a heating and cooling analysis for a base building. This base building has the following thermal characteristics. • The walls are constructed of 2x4 steel wall framing, 16” o.c. with R-13 fiberglass cavity insulation. This wall has a U-value of 0.124 Btu/hr ft2°F, corresponding to an overall R-value of R-8.1. In the Energy-10 program, this wall construction is described by the wall steelstud 4.AREN 3050 Environmental Systems for Buildings I FALL 2005 • The roof is a simple flat roof comprised of a steel pan on steel joists. Rigid board insulation and weatherproofing are installed on top of this pan, providing a continuous thermal and moisture barrier. The insulation has an R-value of 19, giving an overall roof U-value of 0.051 Btu/hr ft2°F. In the Energy-10 program, this roof construction is described by the roof flat, r-19. • The floor is a carpeted slab-on-grade with perimeter insulation. The F2 factor for the floor is 0.50 Btu/hr ft°F. • The windows are standard double-pane clear glass in an aluminum frame. The frame does not have a thermal break. While the glass has a U-value of 0.49 Btu/hr ft2°F, the overall U-value of the window assembly including frame is 0.70 Btu/hr ft2°F. HVAC System Design and Sizing Calculations The HVAC system should be a pair of packaged single zone rooftop units (RTUs), one for each half of the building. For this analysis, you should use a Carrier Model 48TM Weathermaker gas/electric rooftop unit. This model has a standard level of efficiency compliant with ASHRAE Standard 90.1. The units will be placed on the roof and all ducting will be inside. 1. Calculate the design heating load for each HVAC system. This calculation must be done by hand. That is, you may not use a computer simulation program for this task. Note that you do not need to calculation envelope U-values. Rather, you may use the values given above. Assume an infiltration rate of 0.3 ACH. 2. Use the Energy-10 program to determine the heating and cooling equipment size for each system. The Energy-10 inputs for this building are relatively straightforward. One unusual input is the infiltration. Energy-10 allows calculations of infiltration using both an air changes per hour (ACH) and an effective leakage area (ELA). For your analysis, you should change the ELA to zero and use an air change rate of 0.3 ACH. HVAC System Selection Select a pair of RTUs to meet the loads of the two building zones. For this analysis, you should assume an airflow rate corresponding to 400 cfm supply air for each ton of total cooling capacity. Assume that the electrical system is 230 V, 60 hz, single phase. 3. Using the design cooling and heating load information, select specific models of the Carrier Model 48TM Weathermaker RTU to meet the loads of the two zones. Your selection should have the basic form of 48TMmnnn, where m is a letter D, E, or F corresponding to the level of heating capacity, and nnn is the three digit number corresponding to the cooling size. Note that the units are only available in certain sizes. Select the proper cooling size based on the comparison of the total capacity to the total cooling load. Part 2: Economic Assessment of Improved Design The building owner is interested in exploring the economic benefits of a better building design. At this point, the owner would like to consider the potential cost savings of adding more roof insulation, using better wall insulation, better windows, and adding a shading device over the south windows. 4. Design a shading system for the south windows that would be appropriate to shade the windows in the summer but allow passive solar heating in the winter. You should specify a continuous overhang along the entire wall.AREN 3050 Environmental Systems for Buildings I FALL 2005 5.


View Full Document

CU-Boulder AREN 3050 - Commercial Building System Design

Download Commercial Building System Design
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Commercial Building System Design and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Commercial Building System Design 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?