Andy CheungProduct Design CycleDatasheet Specification ExampleAbsolute Maximum RatingsOperating RatingsSlide 6Testing IC’sCorrelationTest Matrix-LDOHandlerSlide 11Test FloorCorrelationTypical Equipment SetupBench SetupCorrelation -Test BoardDropout Voltage & Ground Current MeasurementSlide 18Correlation WorksheetCharacterizationSlide 21Datasheet ReviewSIT LimitsWafer SortWafer Probe StationFinal TestHAPPY THANKSGIVING!!!Andy CheungNew Product Development EngineerMicrel Inc.November 26, 2003Product Design CycleDesignTestApplications/MarketingProductDatasheet Specification ExampleAbsolute Maximum RatingsOperating RatingsTesting IC’s1. Correlation2. Characterization3. Wafer Sort4. Final TestCorrelationTest Matrix by designAll tests listedTypically follows datasheetTests implemented on automatic testerResponsibility of test engineerTMT, Eagle Test SystemsTest Matrix-LDOTest Condition Applied SignalMeasured SignalVin (Pin 1)Vout (Pin 2)Gnd (Pin 3)Ven (Pin 4)Ignd, on Ven = 3V Venable, Vin Ignd 5V open Meas 3VIgnd, off Ven = 0V Venable, Vin Ignd 5V open Meas 0VVdo Iout = 100mAVin=Vout +1V, Iout Vin-VoutVout+1 & sweep Meas 0V 3VVdo Iout = 500mAVin=Vout +1V, Iout Vin-VoutVout+1 & sweep Meas 0V 3VHandlerHandlerTest FloorCorrelationBenchConfirm all TMT dataLearn DeviceFind problemsAccurate measurementsEquipment MethodTypical Equipment SetupOscilloscope with ProbesPair of DC Power Supplies0-25V0-4APair of Digital Multi MetersTest BoardSolder StationParametric AnalyzerSource MeterCurrent ProbeFreeze Spray and Heat gunBench SetupCorrelation-Test BoardDropout Voltage & Ground Current MeasurementDC ErrorsGround wire length100mOhm*500mA = 50 μVIntroduces losses in current measurementsNeed voltage accuracy to 1 or 2 μV4 wire senseKelvin contactsDropout Voltage & Ground Current MeasurementLDO+-VVinSense Node(Kelvin Contact)Normal WireIAmmeterGroundCorrelation WorksheetTEST CONDITION TESTER DATA BENCH DATA UNIT % CHANGEIgnd, on Ven = 3V 1.5 1.45 mA 3.45%Ignd, off Ven = 0V 1 0.95 uA 5.26%Vdo Iout = 100uA 250 240 mV 4.17%Vdo Iout = 500mA 500 475 mV 5.26%CharacterizationCharacterization is Done to: Find the Device’s Capabilities and LimitationsPerformance over TemperatureFind RandomnessResults:Single Insertion Test LimitsSpecification ChangeDetermine ProblemsCharacterizationParts typically follow a normal (gaussian) distribution. Test parts at all possible operating conditions per specification parameters.Typically done on handlers to simulate production environment.Most stringent testing.Datasheet ReviewDevice Realized?Changes?Deletions?Yield Improvements?Problems?SIT LimitsUse characterization data to ensure device operation over temperature.GuardbandsTemperatureTesterWafer SortTightest LimitsWafer TrimBandgapFrequencyWafer Probe Station for Bench TestingGate Stress PadsEnsure Test is CorrectWafer Probe StationFinal TestGuarantee parts operated as written on datasheet.Uses SIT limits generated from characterization.HAPPY THANKSGIVING!!!HAPPY THANKSGIVING!!!Major Test CheckpointsMajor Test CheckpointsCorrelationCorrelationCharacterizationCharacterizationWafer Sort Wafer Sort Final TestFinal
View Full Document