UW-Madison G 777 - Electron Probe Microanalysis EPMA

Unformatted text preview:

Electron probe microanalysis EPMAWhat’s the point?High Vacuum: Need Conductivity!SEM ResolutionSlide 5Slide 6Depth of FieldStigmatismEdge EffectsSecondary electron imagesSE1 and SE2SE1 and SE2…and SE3!BSE imagesSlide 14Variations on a themeEBSD*Forescattered ImageBSE and SE Detectors on our SX51Hitachi SEM DetectorsMosaic ImagesX-ray maps …. And the ClockImage AcquisitionImage StorageSome Image FormatsAcquiring Images in the SEMElectron probe microanalysisEPMA Modified 10/25/08What’s the point? “A picture is worth a thousand words”. The more we know about how images are acquired, the better we can present research results graphically.High Vacuum: Need Conductivity!Above left: uncoated. A charge builds up causes oversaturation (white) and horizontal streaking from beamAbove right: what same area would appear with conductive coatingRight: High vacuum carbon coater (“evaporator” not sputterer)Tradition: insert an object with a sharp edge that produces high contrast relative to the background, crank up the mag and measure the distance (red) where the SE (secondary electron) signal changes from 10 - 90% maximum contrast difference.SEM ResolutionLyman et al, 1990, “Lehigh Lab Workbook”, Fig 2.2, p. 11SEM ResolutionLyman et al, 1990, “Lehigh Lab Workbook”, Figs A2.3, A2.4, p. 191The above 2 scans show the technique (though apparently the proofreader didn’t catch the inverted signal on the left image). The only way to increase resolution is to turn DOWN the beam current, as the plot on the right shows dramatically -- the current is a few tens of picoamps, not nanoamps.However, the approach apparently used today (e.g. our Hitachi field service engineer) is to take his “test sample” (gold sputtered on graphite substrate) and with optimizedSEM Resolutioncontrast, find the narrowest spacing between 2 gold blobs and define that as the “resolution”.A strength of the SEM is the enhanced depth of field compared to optical microscopy as shown above for the radiolarian Trochodiscus longispinus. Optical image has only a few micron depth of field (=plane in focus), whereas SEM images can be made to be in focus for hundreds of microns (e.g. increasing working distance) Depth of FieldGoldstein et al 2003 Fig 1.3Imperfect magnetic lenses (metal machining, electrical windings, dirty apertures) can cause the beam to be not exactly round, but “astigmatic”. This can be corrected using a “stigmator”, a set of 8 electromagnetic coils.Top left: original “poor” imageTop right: underfocus with stigBottom left: overfocus with stigBottom right: image corrected for astigmatism. Marker = 200 nmStigmatismGoldstein et al 2003 Fig 2.24Edge EffectsEdges of objects can appear to be brighter in SE and BSE images, because electrons can be emitted not only from the top but the side, artifically making that part of the image brighter. This can lead to some incorrect conclusions for BSE images.Reed 2005 Fig 4.3Secondary electron imagesSE imaging: the signal is from the top 5 nm in metals, and the top 50 nm in insulators. Thus, fine scale surface features are imaged. The detector is located to one side, so there is a shadow effect – one side is brighter than the opposite.Everhart-Thornley detector: low-energy secondary electrons are attracted by +200 V on grid and accelerated onto scintillator by +10 kV bias; light produced by scintillator (phosphor surface) passes along light pipe to external photomultiplier (PM) which converts light to electric signal. Back scattered electrons also detected but less efficiently because they have higher energy and are not significantly deflected by grid potential. (image and text from Reed, 1996, p. 37)SE1 and SE2The picture gets a little more complicated … secondary electrons in fact can be generated and detected from more than just the “landing point” of the E0 beam (SE1’s). As the electron scatters away from the impact spot, if it stays near the surface, a second generation (SE2’s) can be generated and detected -- these will cause the SE image to be less sharp.Solution: go to lower E0 (5 kV or less is mentioned by Goldstein)Goldstein et al 2003 Fig 3.20SE1 and SE2…and SE3!And in the real world it may be even more complicated … backscattered electrons may bounce off the chamber walls, or the bottom of the column, generating SE3’s. Because the E-T detector has a positive bias to attract the low energy SEs, these extraneous signals can add more noise to the image. This is especially problematic at high E0s and is a reason not to expect high resolution SE images at high kV values.Goldstein et al 2003 Fig 4.20BSE imagesBSE imaging: the signal comes from the top ~.1 um surface). Above, 5 phases stand out in a volcanic ash fragmentThere are several different types of detectors used to acquire BSE images:(1) Everhart-Thornley detector can have a -50 ev bias put on the grid to reject secondary electrons, so only BSEs get thru -- however this is not useful at fast, TV scanning rates, i.e. moving the stage. (2) Robinson detector — a modern version of the E-T for BSE at TV rates. Must be inserted and retracted.(3) Solid state detector — which is most commonly used today on electron microprobes and many SEMs. Permanently mounted below polepiece.BSE imagesBSE imaging: the signal comes from the top ~.1 um surface; solid-state detector is sensitive to light (and red LEDs). A solid-state (semi-conductor) backscattered electron detector (a) is energized by incident high energy electrons (~90% E0), wherein electron-hole pairs are generated and swept to opposite poles by an applied bias voltage. This charge is collected and input into an amplifier (gain of ~1000). (b) It is positioned directly above the specimen, surrounding the opening through the polepiece. In our SX51 BSE detector, we can modify the amplifier gain: BSE GMIN or BSE GMAX.Goldstein et al, 1992, Fig 4.24, p. 184There are several alternative type SEM images sometimes found in BSE or SE imaging: (left) channeling (BSE) and (right) magnetic contrast (SE). I have found BSE images of single phase metals with crystalline structure shown by the first effect, and suspect the second effect may be the cause of problems with some Mn-Ni phases.Crystal lattice shown above, with 2 beam-crystal orientations: (a) non-channeling, and (b) channelling. Less BS electrons get out in B, so darker.From Newbury et al, 1986, Advanced Scanning Electron Microscopy and X-ray Microanalysis,


View Full Document

UW-Madison G 777 - Electron Probe Microanalysis EPMA

Documents in this Course
Load more
Download Electron Probe Microanalysis EPMA
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Electron Probe Microanalysis EPMA and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Electron Probe Microanalysis EPMA 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?