View Full Document

Lighting Proposal Memo



View the full content.
View Full Document
View Full Document

3 views

Unformatted text preview:

2010 Lighting Proposal Memo Daskalakis Athletic Center Philadelphia PA Britnei Godusky Lighting Electrical Faculty Advisor Dr Houser 9 13 2010 2 Lighting Proposal Memo Daskalakis Athletic Center Philadelphia PA For the lighting design portion of my senior thesis I propose to concentrate on four main spaces to meet the established lighting electrical thesis requirements with the possibility of a fifth for an extra daylighting focus The proposed spaces are listed below large work space open office collaboration area special purpose space restaurant circulation space lobby entrance outdoor space building fa ade possible daylighting focus gymnasium A more detailed description of each space follows large work space open office collaborative workspace Description The collaborative workspace is located on the eastern side of the first level just north of the main entrance and security desk The space contains three offices enclosed in open cubicles and a central conference table for 6 8 individuals A corridor lines the cubicles providing passage to the director s office and main conference room This is the only office space in the Daskalakis Athletic Center so all administrative tasks take place here The collaborative space will be used primarily for desk tasks the reading and writing of various print sizes and multi person collaboration This space also contains computers with usage taking place along the western wall shown below in image 2 as well as within the cubicles All phone calls and communications will also take place within this area Image 1 Collaborative Workspace Conference area Image 2 Collaborative workspace computer usage Lighting Proposal Memo Daskalakis Athletic Center Philadelphia PA Dimensions The collaboration space encompasses approximately 1 100sf and is 9 0 from floor to ceiling The central square conference portion of the space is 18 x 24 The cubicle walls are 6 tall The conference area and open cubicles are separated by an 8 10 circulation corridor



Access the best Study Guides, Lecture Notes and Practice Exams

Loading Unlocking...
Login

Join to view Lighting Proposal Memo and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Lighting Proposal Memo and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?