PHYS 210 Spring 2006 Optics and Microscopy In this lecture we will briefly discuss optics and various types of microscopes. Geometric optics Simple equations for the effects of thin lenses can be obtained following the rules of geometrical optics: 1) Rays going parallel to the axis on one side of the lens pass through the focal point on the other side 2) Rays going through the center of the lens are not deflected. From these rules it follows from simple geometry that where o is the distance from the object to a convergent lens, i is the distance from the lens to the image and f is the focal length of the lens. Similarly, one can show that the magnification is S1/S0 = i/o. For example, to obtain large magnification one needs iπo and therefore o~ f. Wave optics On length scales comparable to the wavelength of light its propagation is no longer governed by geometric optics. Light diffraction begins to play a large role, for example, allowing the light to pass around small obstruction. Diffraction also limits the minimum size of an object that can be seen with light to approximately the wavelength of light. More precise calculations show that the spatial resolution of a microscope is given by NAd /22.1minλ=, where the numerical aperture NA defines the light collection ability of the lens, NA= sin(α), where α is the opening angle, see picture to the right. Numerical aperture is larger for shorter focal length lenses, but is generally smaller than 1. Thus the maximum spatial resolution that can be obtained with visible light is on the order of 0.5 μm. Wave Microscopy As shown above, the maximum resolution one can obtain with optical microscope is on the order of 0.5 μm. It can be improved somewhat using shorter wavelength and sub-wavelength interference tricks. For example, optical lithography used in modern chip manufacturing reaches resolution of about 50 nm with laser wavelength of 193 nm. Another way to increase the resolution is to use other particles, such as electrons, with short de Broglie wavelength. An electron accelerated to 200 keV, for example, has a de Broglie wavelength 5/== phλpm. fio111=+f oi S1 S0 αInstead of lenses, electric and magnetic fields are used to shape and image electron beams. However, since possible configurations of electromagnetic fields are limited by Maxwell equations, it is much harder to achieve diffraction-limited performance. Only recently development of effective correction coils for spherical aberration enabled resolution below 0.1 nm. Force microscopy Another way to image the top layer of a sample is to literally drag a mechanical tip along the surface. This technique is known as atomic force microscopy. The height of the tip can be measured using laser interferometry with better than 0.1 nm resolution. A surface image is obtained by scanning the tip across the sample. The horizontal resolution is about 1 nm, limited by how sharp the tip is, typically a few atoms across. A higher resolution image for conductive samples can be obtained using electron quantum tunneling effects. The main features of quantum tunneling can be obtained from a simple solution to the Schrödinger equation assuming a constant potential V>E in the gap between the conducting tip and the sample: kxkxexxPEVmkexxExVxxm222222)0()()()(2)0()()()()(2−−==−===+∂∂−ψψψψψψψhh Hence, the tunneling current depends exponentially on the distance between the tip and the sample. This allows one to obtain sub-atomic level horizontal resolution because electrons will tunnel only from the very tip of the sample. Scanning tunneling microscopes (STM) are fairly simple and with good vibration isolation can achieve a resolution of 0.1 nm or better. Tip Sensing laser Tip SampleTunneling


View Full Document

Princeton PHY 210 - Microscopy

Download Microscopy
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Microscopy and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Microscopy 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?