Power MeterTechnical RequirementsVoltage-Sensing CircuitDesign ExplanationSlide 5Simulation ResultsPower Meter Power Meter ECE 4512 Senior Design IDepartment of Electrical & Computer EngineeringMississippi State UniversityTechnical Requirements•Voltage-sensing circuit (0 to 120 Vrms)•Current-sensing circuit (0 to 30 A)•Power Measurement Range (0 to 3600 W)•Display (4-digit LCD)•Power Factor Calculation (DS87C520 Microcontroller)•Energy Measurement (0 to 86.4 kWhrs)•Power (9 V Battery)•Tolerance (+/- 3%)•Size & Packaging (Plastic enclosure – 4” x 8” x 1.5” (W x L x D))Voltage-Sensing CircuitDesign Explanation12RR))(*21(1234VVRRVo IDA (Instrumental Differential Amplifier)•High-input impedance•Filtered noise•Overall gain of 1 calculated as follows:Design ExplanationSimulation Results Voltage Input (Vp-p) Vo (Vp-p) Vo Scaled by 36 Percent error (%)180 5.0103 180.371 0.206170 4.7319 170.348 0.205160 4.4536 160.33 0.206150 4.1752 150.307 0.205140 3.8969 140.288 0.206130 3.6185 130.266 0.205120 3.3402 120.247 0.206110 3.0618 110.225 0.205100 2.7835 100.206 0.20690 2.5052 90.1872
View Full Document