Unformatted text preview:

STRUCTURAL DRAFTINGASSEMBLY CLEARANCE DIMENSIONSIn order for members to assemble readily, clearances are required between beams and columns or beams and beams. The dimension values can be found in the Dimensions and Properties Tables of the AISC manual.Clearance Dimensions for Beams Connecting to Beams:Dimension A: Is the given center to center distance from the main beams. This dimension is found on the framing plans.Dimension B: Dimension from the backs of the connection angles(A - (C1 + C2))Dimension C: Clearance dimensions for the connection angles. This dimension is also referred to as "Setback." Note that the C dimension is calculated using the beam that is being connected to. C = (tw / 2) + 1/16Dimension D: Actual length of connection beam. This is the dimension that the fabricators need to cut the beam to proper length to fit in the assembly.(D = B - (E1 + E2)Dimension E: Nominal Setback clearance for beam. This is generally 1/2".For Example: Given a W12 x 35 is connected to two W18 x 60 beams, calculate the following dimensions:A = 26'- 4" (given on the framing plan drawing)C = (tw /2) + 1/16 = 1/4 + 1/16 (The (tw /2) value is taken from the W18 x 60 beam not the W12 x 35)E = 1/2B = (A - (C1 + C2)) = 26'-4" - (5/16 +5/16) = 26' - 3 3/8"D = B - (E1 + E2) = (26'-3 3/8") - (1/2 + 1/2) = 26' - 2 3/8"E D EC B CA1STRUCTURAL DRAFTINGASSEMBLY CLEARANCE DIMENSIONSClearance Dimensions for Beams Connecting to Columns:Given the beam (W6 x 12) connected to column A and column B, the total length of the beam can be calculated as follows:Center to Center distance of Column A and Column B 24' - 0"Column A: tw/2 + 1/16 0' - 0 4/16"Column B: tw/2 + 1/16 0' - 0 4/16"Setback at Column A 0' - 0 1/2"Setback at Column B 0' - 0 1/2"Total Length of Beam W6 x 12 23' x 10 1/2"Clearance Dimensions for Beams Connecting to Columns:Given the beam (W6 x 12) connected to column A and column B, the total length of the beam can be calculated as follows:Center to Center distance of Column A and Column B 20' - 0"Half the depth of Column A + 1/16 0' - 6 3/16"Half the depth of Column B + 1/16 0' - 6 3/16"Setback at Column A 0' - 0 1/2"Setback at Column B 0' - 0 1/2"Total Length of Beam W10 x 49 18' x 10 5/8"W 6 X 12BAW 12 X 40 W 12 X 4024' - 0"W 10 x 49BAW 12 X 26 W 12 X 2620' - 0"2STRUCTURAL DRAFTINGASSEMBLY CLEARANCE DIMENSIONSCope CutsWhen the tops of beams are to be flushed, a notch must be cut into the connecting beam to prevent interference with the flange of the other beam. Such a notch is called a cope, block, or cut. It is the practice of the structural detailer to draw the depth dimension to scale so that the relation of the detail is correct and so the fabricator can interpret the relation of the holes to bolts or other holes more readily.The intersection of the horizontal and vertical cuts (re-entrant cut) is shaped to a smooth radius to provide a fillet at this point. Although most shops routinely provide these fillets, they should always be shown on shop details. Anapproximate minimum radius to which this corner must be shaped is 1/2 inch (13th Edition AISC manual, Part 9).Q1 = k distance This is a minimum dimension. Q1 can never be smaller than the k-distanceQ2 = ((bf - tw) ¸ 2) + 1/2 The Q2 dimension is measured from the back of the connection angleNote: Q1 and Q2 are rounded to the nearest


View Full Document

CCAC EDD 141 - STRUCTURAL DRAFTING

Download STRUCTURAL DRAFTING
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view STRUCTURAL DRAFTING and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view STRUCTURAL DRAFTING 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?