Rice PHYS 332 - Spectroscopy of Hydrogen Isotopes

Unformatted text preview:

Rice University Physics 332 SPECTROSCOPY OF HYDROGEN ISOTOPES I. INTRODUCTION.................................................................................................................................... ....... ..........2!II. THEORETICAL CONSIDERATIONS .................... ....... ........................... ....... ....... ....... ....... ........................... ...3!III. MEASUREMENTS ...................................................................................................................................... ....... ..4! May 20122 I. Introduction The energy levels of atoms are largely determined by the Coulomb interaction between the electrons and the nucleus, but other interactions may also be present. These additional interactions manifest themselves as shifts or splittings of the observed spectral lines relative to the lines which would occur if the electrons moved in a pure central potential. For example, the fine structure splitting arises from electron-electron Coulomb interaction in multi-electron atoms and from the spin-orbit interaction of the moving electrons with the nuclear electric field. Smaller splittings, called hyperfine structure, arise from non-electrostatic interactions with the nucleus. For example, if the nucleus has a spin there can be magnetic interactions which perturb and split some of the electronic levels. Differences in the nuclear mass and volume can also shift the atomic energy levels between isotopes of the same element. As an example, we will observe the differences between the visible-light emission spectra of hydrogen and deuterium. The observed shifts are attributed to the different masses of the nuclei, yielding an estimate of the mass ratio. The next section outlines the pertinent atomic physics. Section III describes the measurements and their analysis. Additional information on the spectrometer and the lock-in system can be found in the instruction manuals, available in the lab.3 II. Theoretical considerations The energy levels of the hydrogen atom, including the effect of a finite nuclear mass M, are given by En=hcRn21+mM! " # $ % & '1 (1) where R is the Rydberg constant for an infinite-mass nucleus, m is the mass of the electron, M is the mass of the nucleus, and n = 1, 2, 3, .... The Balmer series of lines, which fall in the visible spectrum, are due to transitions from n = 3, 4, 5, 6... to n = 2. The corresponding wavelengths are given by !=1R1+mM" # $ % & ' 1nf2(1ni2" # $ $ % & ' ' (1 (2) where ni, nf are the initial and final level numbers of the transition. Evidently a measurement of the wavelength difference between spectral lines from hydrogen and deuterium would determine the relative mass of the isotopes. (Deuterium was actually discovered this way. See Phys. Rev. 40,1 (1932))4 III. Measurements The objective is to measure as accurately as possible the wavelength difference between several of the Balmer lines of hydrogen and deuterium. Since the difference is small, of order 0.1 nm, it is not feasible to measure the individual wavelengths to sufficient accuracy. The apparatus is sketched in Fig. 1. Briefly, light from a gas-discharge tube containing both hydrogen and deuterium is analyzed by a scanning spectrometer. Light intensity as a function of wavelength is measured by a photomultiplier tube connected to a lock-in amplifier system and recorded on a paper chart. Using the spectrometer and chart recorder calibrations and the known parameters of the hydrogen atom, one can determine the deuterium mass from the measured difference in wavelength. Since one of the main purposes of this exercise is to accurately measure a small shift, it is important to establish the errors in the measurement. The basic measurements should be done in such a way as to obtain a realistic standard deviation. If there are uncontrolled effects which might lead to systematic errors they should also be discussed and the likely effects estimated, if possible. For reference, we list below the accepted values of the wavelengths involved in this experiment and some useful physical constants. Your data should stand on their own, however, and it is not intended that you compare your results with the accepted value to define an "error". Table I. Constants for the hydrogen-deuterium system Infinite-mass Rydberg constant: R = 1.0973731 x 107 m-1 Mass of electron: 9.109534 x 10-31 kg Mass of hydrogen nucleus: 1.672649 x 10-27 kg Mass of deuterium nucleus: 3.343637 x 10-27 kg Fig. 1 Block diagram of apparatus for H/D spectroscopy. choppercontrolsweepcontrollock-inchart recorderhighvoltagelamp supplyspectrometerdischargelamplensphotomultiplier5 Table II. Wavelengths of the hydrogen spectrum label ni !H (nm) " 3 656.285 # 4 486.133 $ 5 434.047 % 6 410.174 7 397.007 8 388.906 9 383.540 A. Setup The discharge lamp is started by turning on the high voltage supply. The light output will increase for the first 3-4 minutes of operation and then slowly decline. You should, therefore allow the tube to warm up briefly before starting a measurement and turn it off if there will be an interval between measurements. The lamp and a lens are placed on the optical bench in front of the spectrometer approximately as indicated in Fig. 2. By using a lens we increase the amount of light entering the spectrometer and separate the electrically noisy arc discharge from the sensitive detection electronics. The maximum amount of light is transferred into the spectrometer when the lens forms an image of the discharge on the entrance slit. Adjust the positions of the lamp and lens as needed to get a clear image centered on the slit. You will probably need to remove the chopper from the optical path so that you can see the slits and locate the image properly. Install the chopper near the slit, with the outer ring of holes in the chopper disk vertically centered on the spectrometer slit. Since the holes are fairly short, set the spectrometer slit height to 1 cm (not the maximum of 2 cm) to ensure that the chopper blocks all the incoming light. High voltage for the PMT comes from a precision supply. Start with a setting of about 400 V negative, and do not exceed the tube rating of 1250V. The signal


View Full Document

Rice PHYS 332 - Spectroscopy of Hydrogen Isotopes

Download Spectroscopy of Hydrogen Isotopes
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Spectroscopy of Hydrogen Isotopes and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Spectroscopy of Hydrogen Isotopes 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?