DOC PREVIEW
Computer Room Air Conditi

This preview shows page 1-2-3-4 out of 11 pages.

Save
View full document
View full document
Premium Document
Do you want full access? Go Premium and unlock all 11 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 11 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 11 pages.
Access to all documents
Download any document
Ad free experience
View full document
Premium Document
Do you want full access? Go Premium and unlock all 11 pages.
Access to all documents
Download any document
Ad free experience
Premium Document
Do you want full access? Go Premium and unlock all 11 pages.
Access to all documents
Download any document
Ad free experience

Unformatted text preview:

Computer Room Air ConditionerGeneral The computer room is cooled by a 5 ton air conditioner. The compressor and condenser part of the unit is located outside on the north wall of the Ops Bldg. Under the window by Dave Woods desk. The evaporator is integral to the blower /fan unit in the computer room. The compressor starts and stops as required to maintain temperature in the room at 70 degrees. There is no heat just cooling available. The fan/blower unit runs continuously. There is also 2 humidifiers that are run with the blower and use RO water from under the sink in the main bathroom. The blower has been equipped with a automatic temperature and humidity controlled louver that will let outside air in if the temperature is below a certain temperature (currently set at 55 deg) and below a set humidity (currently set at 60%) . This functions as an economizer reducing the run time on the compressor during times when the outside is cold enough to maintain the temperature in the room.There is also a temperature alarm (see fig 4) by the fax machine that indicates if the computer room air conditioner is down by alerting when the temperature gets too high. It is essential that quick action be taken once the room temperature gets above 75 deg to avoid hardware failure. Common failure modes:1. Fan blower motor fan belt breaks2. Compressor stops for high or low pressure3. Compressor trips on incoming power4. Evaporator coils freeze upIn all of these cases knowledge of mechanical/electrical and HVAC systems is required to fix the problem. As a result we have implemented procedures to bring in outside air to help cool the room. We will also need to start turning off unused equipment and heat loads. The success of these procedures will depend to large extent what the outsidetemperature is. If hot outside we will likely have to shut down all essential computers and will not be able to observe. This needs to start as soon as possible.What to do when the temperature alarm goes off:1. Go into the computer room and verify if the fan/blower is running 1a. Determine outside air temp 2. Call Fritz or Jon B.3. Call Mark or Ben (I’ll need to know the answers to 1 and 1a.)If the fan/blower unit is running then immediately :1. On right side of blower unit move toggle switch to “Bypass”(see Fig 1) You should hear if the outside louver motor opensIf so great , regardless continue2. On left side of outside air inlet on the exterior east wall of the ops bldg slide up the cover plate on the small box attached to the hood and set temperature controller to 0 deg (see Figure 2 and 3 ) If louver motor did not activate in step 1 it should now unless it was already open3. Prop open door to computer room4. Close door by bathroom to instrument lab5. Close door to Ops extension area6. Close door between kitchen and supply area7. Close all outside ops bldg doors doors/windows8. Open door to 3.5m Arcade9. Turn on Arcade fan by selecting “hand” on the front panel Arcade Fan should start – lots of noise (see Fig 5) 10. Get large grey fan (5ft tall) (see Fig 7) from base of 3.5m and roll down to computer room11. Set fan in door way of computer room and turn on , out blowing air out of the computer room. 12. If outside temp is warmer than 30 degs--- There is a small louvered vent in the upper right corner on the east wall of the computer room, Remove screen and prop this louver open 13. Monitor room temperature14. If temperature exceeds 80 deg and you can not reach Fritz or Jon start shutting down all equipment in the computer room that you know how to.If the fan/blower unit is NOT running then immediately :1. on right side of blower unit move toggle switch to “Bypass”(see Fig 1) You should hear if the outside louver motor opensIf so great , regardless continue2. Behind the fan/blower unit is a box that directs air from the outside louvers to the fan. There is a cover on this box held by a couple sheet metal screws. Remove this topcover. (see Fig 6) 3. On left side of outside air inlet on the east exterior wall of the ops bldg slide up the cover plate on the small box attached to the hood and set temperature controller to 20 deg (see Fig 2 and 3) If louver motor did not activate in step 1 it should now unless it was already open4. Prop open door to computer room5. Close door by bathroom to instrument lab6. Close door to Ops extension area7. Close door between kitchen and supply area8. Close all outside ops bldg doors doors/windows9. Open door to 3.5m Arcade10. Turn on Arcade fan by selecting “hand”Arcade Fan should start – lots of noise (see Fig 5) 11. Get large grey fan (5ft tall) from base of 3.5m and roll down to computer room. (See Fig 7) 12. Set it near the fan/blower unit and turn on blowing air down the computer room towards the door. 13. In the base of the 3.5m telescope get all of the box fans available and set up in computer room to circulate air towards the door.13. There is a small louvered vent in the upper right corner on the east wall of thecomputer room, Remove screen and prop this louver open 13. Monitor room temperature14. If temperature exceeds 82 deg and you can not reach Fritz or Jon start shutting down all equipment in the computer room that you can.QuickTime™ and a decompressorare needed to see this picture.Fig 1 Fresh air inlet louver bypass and humidity controlQuickTime™ and a decompressorare needed to see this picture.Fig 2 Fresh air inletQuickTime™ and a decompressorare needed to see this picture.Fig 3 Fresh air inlet louver temperature controlQuickTime™ and a decompressorare needed to see this picture.Figure 4 Computer Room Temperature alarmQuickTime™ and a decompressorare needed to see this picture.Fig 5 Arcade Fan controllerFig 6Computer Room Fan/Blower unitFig 7 Extra


Computer Room Air Conditi

Download Computer Room Air Conditi
Our administrator received your request to download this document. We will send you the file to your email shortly.
Loading Unlocking...
Login

Join to view Computer Room Air Conditi and access 3M+ class-specific study document.

or
We will never post anything without your permission.
Don't have an account?
Sign Up

Join to view Computer Room Air Conditi 2 2 and access 3M+ class-specific study document.

or

By creating an account you agree to our Privacy Policy and Terms Of Use

Already a member?